JB and JBX Multi-Fuel Burners
The Autoflame System is available as an option on JB1, JB2 and JB3 units.
Autoflame is a standard feature of the JB4 units.
For over 65 years the Webster name has stood for high quality gas and oil burners. Webster burners are used in a wide variety of commercial and industrial applications, ranging from steam and hot water boilers, air heaters, dryers, kilns, incinerators and many other combustion applications. Our strong emphasis on quality, safety performance and research assures Webster customers of the most reliable technically advanced combustion equipment for maximizing efficiency.
OPERATION
Webster burners offer years of dependable efficient operation. Designed with ease of serviceability in mind, Webster burners are available with a wide variety of control options from on-off to full modulation utilizing the latest flame safeguard technology options available.
APPLICATIONS
Versatility and flexibility are prime considerations in Webster’s burner design. JB series units can be adapted to fire in most any furnace configuration and combustion environment. Our exclusive flame retention combustion head design maintains stable and efficient combustion in a wide variety of furnace configurations and conditions. Mechanical pressure atomization is standard for firing #2 fuel oil with a Webster burner, however, air or steam atomization is available for both #2 or heavier grades of fuel oil applications.
PACKAGED FOR EASY INSTALLATION
Webster burners are completely factory wired, assembled and fire tested ready for installation and hook-up to fuel and electrical supplies. Typical installations are up and running in just a few hours time.
FACTORY FIRE TESTED
Webster burners are test fired at the factory in an environment that simulates actual field operating conditions. This extra measure of testing assures Webster customers that each burner is functional and ready for trouble free start-up and operation.
WEBSTER ENGINEERING’s “AUTOFLAME”
MICRO MODULATION CONTROLS
Micro Modulation is the new, high technology answer to burner control!!
AUTOFLAME FEATURES
- Eliminates Fuel and Air Linkage Controls
- Eliminates Linkage Hysterisis
- Servo Motor Controlled Fuel and Air Controls
- Valve/Servo Positioning within one tenth of an Angular Degree
- Absolute Fuel / Air Repeatability, Throughout the Firing Range
- Fuel Savings of 7 to 12 Percent
- Intelligent Boiler Sequencing
- Multiple Fuels
- Improved Combustion Quality
- EGA Compatible
- DTI Compatible
- UL/ULC Approved
- NEMA 4 Rated
- “Golden Start” burner lightoff settings
MAXIMUM INPUT CAPACITY RATINGS - JB AND JBX MODELS 1, 2, 3 AND 4
BURNER |
GAS |
LIGHT OIL |
HEAVY OIL |
BOILER HP |
MBH |
GPH |
GPH |
OUTPUT |
|
1 |
2800 |
20.00 |
18.7 |
67 |
2 |
6800 |
48.6 |
45.3 |
162 |
3 |
14000 |
100.0 |
93.3 |
333 |
4 |
17500 |
125.0 |
116.7 |
417 |
INPUT CAPACITIES BASED UPON:
- 1000 feet above sea level. Capacity will decrease 4.0% for each additional 1000 feet of elevation.
- -0.01" W.C. furnace draft. Capacity decreases with pressurized furnace 1.5% for each 0.25" W.C. in furnace combution chamber pressure.
- Output BHP equivalent ratings based on operation at 80% combusion efficiency.
- Gass input based on 1000 BTU/cubic foot and 0.64 specific gravity.
- Oil input based on 140,000 BTU/gallon light oil and 150,000 BTU/gallon heavy oil.
TYPICAL DIMENSIONS FOR MODELS JB AND JBX 1, 2 AND 3 - INCHES
MODEL |
A(JB) |
A(JBX) |
B1 |
B2 |
C1 |
C2 |
D |
E |
H1 |
H2 |
*L1 |
L2 |
W |
1 |
**4 |
**4 1/2 |
14 |
15 |
9 |
14 |
7 1/4 |
11 |
11 |
5 |
25 |
34 |
23 |
2 |
**4 |
**4 1/2 |
15 |
16 |
10 |
14 |
9 1/4 |
14 |
15 |
8 |
29 |
38 |
28 |
3 |
**4 |
**4 1/2 |
16 |
16 |
12 |
18 |
11 1/4 |
17 |
18 |
12 |
37 |
46 |
28 |
* Add 14" to Dimension L1 for heavy oil burners. Use Dimension L2 for alternate control cabinet location.
** Standard Dimensions may vary depending upon application.

TYPICAL DIMENSIONS FOR MODELS JB AND JBX 4 - INCHES
MODEL |
A(JB) |
A(JBX) |
B |
C |
D |
E |
H |
*L |
W |
4 |
**2 |
**6 1/2 |
15 |
23 |
13 1/8 |
18 |
26 |
48 |
32 1/2 |
* Add 6" to Dimension L for light oil units. 12" for heavy oil.
** Standard Dimensions may vary depending upon application.